Container securing · lifting · moving — Southern Africa WhatsApp 076 546 2803  ·  +27 (0)11 609 7873  ·  info@twistlockafrica.co.za
Operation 07 · Fabricating · Corner castings

Corner Castings — Aluminium — Set of 8 (2 × TL, TR, BL, BR) — 178 × 162 × 118 mm

TLA-FAB-CC-SET8-AL
3D on request

Supplied by Twistlock Africa

Ask an engineer

No prices online — quotations are prepared per application and quantity, usually within one business day; a more involved enquiry may take a little longer. Compare all 15 corner castings variants.

Replacement ISO corner castings for shipping container repair; manufactured from low-temperature steel (-40°C rated); sold individually by corner position (TL, TR, BL, BR) or as a set of 8.

Specifications
MaterialAluminium alloy A356 (cast) or EN AW-7020-T6 — specify the grade on order
PositionTwo of each position — a full container
Size178 × 162 × 118 mm (per casting, ISO 1161 geometry)
Design load — Stacking — top fitting (load offset 25.4 × 38 mm)687 kN (EN AW-7020-T6) · 459 kN (A356-T6)
Design load — Stacking — bottom fitting on flat support875 kN (EN AW-7020-T6) · 585 kN (A356-T6)
Design load — Stacking — bottom fitting (load offset)687 kN (EN AW-7020-T6) · 459 kN (A356-T6)
Design load — Lifting — top fitting (twistlock, hook or shackle)142 kN (EN AW-7020-T6) · 95 kN (A356-T6)
Design load — Lifting — bottom fitting (sling at 30°)284 kN (EN AW-7020-T6) · 190 kN (A356-T6)
Design load — Longitudinal restraint — two bottom fittings219 kN (EN AW-7020-T6) · 146 kN (A356-T6)
Design load — Vertical restraint — top and bottom fittings182 kN (EN AW-7020-T6) · 122 kN (A356-T6)
Design load — Misgather — any fitting139 kN (EN AW-7020-T6) · 93 kN (A356-T6)
Mass≈ 28.8 kg
StandardDimensions to ISO 1161. Design loads derated from ISO 1161:2016 by tensile strength against SCW480 (×0.73 EN AW-7020-T6, ×0.49 A356-T6) — not ISO 1161 strength-rated
Features
  • World-standard ISO 1161 components forming the basis of all intermodal container transport
  • Top and bottom castings are interchangeable (same size and openings)
  • ISO 1161 specifies geometry and tolerance, not mass — mass varies with the casting pattern and wall thickness within tolerance
  • Full engineering drawings available on request
  • Fundamental structural components — every replacement enables corner-to-corner connection and lifting with standard equipment
Typical applications

Container fabrication and repair; replacement of damaged or corroded corner castings.