The stacking, racking and wall-strength test loads ISO 1496-1 requires a Series 1 container to withstand — the figures container hardware is specified against.

Stacking Loads
Maximum gross mass (20 ft)30 480 kg (30.48 t)
Maximum gross mass (40 ft)32 500 kg (32.5 t)
Maximum gross mass (40 ft HC)32 500 kg (32.5 t)
Maximum gross mass (45 ft)32 500 kg (32.5 t)
On-chassis stacking test load1.8× Rg per corner
Standard stack test (ship)9× Rg total
TLA vertical spacer min design load250 kN per corner casting
Racking, Lifting & End-Wall Forces
Longitudinal racking test75 kN
Transverse racking test150 kN
Four corner lifting1.25× Rg per corner
Under-wing test1.25× Rg
End wall test force0.4× Pg (P = payload)
Floor strength — concentrated load7 260 kg over 284 cm²